INSTALLATION OF NACHURS FERTILIZER EQUIPMENT

Coming Spring 2010

 

CALIBRATION PROCEDURE

1) Determine the recommended application rate/acre for NACHURS liquid fertilizer.

2) Calculate the distance required to drive in field for each nozzle to treat 1/128 acre.
(ounces collected from one nozzle equals gallons per acre)

FORMULA:
Distance to Drive (feet) / Row Width (inches)

3) Drive required distance and collect output from one nozzle (check row and deep placement separetely).

4) Adjust to obtain desired output

  • Pressure pump:
    Adjust pressure, speed or nozzle tips
  • Squeeze pump:
    Adjust sprocket size

Example: Distance for each nozzle to spray 1/128 acre (one ounce collected per nozzle equals one gallon per acre)

Average Spacing (inches)
Distance (feet)
Average
Spacing
(inches)
Distance
(feet)
6.............
681
22...........
186
8.............
510
24...........
170
10...........
408
30...........
136
12...........
340
36...........
113
14...........
292
38...........
107
16...........
255
40...........
102
18...........
227
42...........
97
20...........
204
48...........
85
 